Dispense Pump – Syringe Fluid Level
Available for all MAX Series and DS Series dispense platforms is pump syringe fluid level detection, and GPD’s programmable controllers
The optional Level Detect option uses a capacitive proximity sensor that generates an electrical field (Figures 1 & 2) to identify the level of material in a material syringe.
Unlike an optical sensor, the Level Detect is not subject to syringe color or label limitations. The sensor position, rotation, and orientation are easy to adjust. The Level Detect is compatible with all GPD Global pumps and syringe sizes from 5 cc to 55 cc.
Shown on pump models: Precision Auger, NCM5000, PCD3H, and PCD4H
How the Dispense Pump – Syringe Fluid Level Works
The sensor lamp turns on (Figure 3), setting an “OK to Process” flag when the syringe is full or the fluid level is present above the Level Detect sensor. When the fluid level drops below the Level Detect sensor, the sensor lamp turns off (Figure 4), and a “Fluid Level is Low” system message (Figure 5) prompts the operator to add fluid.
Syringe Sizes and Part Numbers
Syringe Size | Part Number |
5 cc | 22293236 |
10 cc | 22293219 |
30 cc* | 22293209 |
55 cc | 22293218 |
*Pump models shown above with 30 cc syringe. *Level Detect is compatible with any GPD Global dispense pump. |
Downloads for Dispense Pump Syringe Fluid Level Detect
Manual – Level Detect User Guide